Amaron Quanta 12AVL007

0 Reviews Write a review
Availability In Stock

The industrial segment SMF-VRLA (Valve Regulated Lead Acid) battery for UPS applications is built to perform.

In short, the lifeline to your UPS applications.

AMARON QUANTA is a product of fail-safe, fool-proof battery technology, produced and tested in our premier manufacturing facility. Built to the highest technical competence in its class, the QUANTA is an example of Amara Raja’s commitment to bringing the best of technology to your table

Description

Specification

Notes:

The above data are average values per battery and can be obtained within five charge/discharge cycles.

A tolerance of ±5% is applicable for the above constant power discharge and constant current discharge values.

Recommended to follow IEEE-485 Standard for battery sizing (in terms of Aging Margin and Design Margin) for optimal performance and life.

Considerable voltage drop across cables, if any, shall be considered during battery sizing.

General Specifications:

Nominal Voltage: 12V

Rated Capacity: 7 Ah / C20 / 1.75VPC / 27°C

Dimensions (±2mm):

Length: 151mm (5.94 in.)

Width: 65mm (2.55 in.)

Total Height: 100mm (3.93 in.)

Weight:

2.2 Kg (4.85 lbs.) ±5%

Terminal Type:

F2 (Faston tab)

Capacity @ 27°C:

6.4 Ah (10hr, 0.64 A, 10.5 V/battery)

5.9 Ah (5hr, 1.18 A, 10.2 V/battery)

4.56 Ah (1hr, 4.56 A, 9.6 V/battery)

Case Material:

Acrylonitrile Butadiene Styrene (ABS)

Internal Resistance (IR):

Approx. 19.0 mΩ for a fully charged battery (27°C)

Maximum Discharge Current (5 sec):

105 A

Operating Temperature Range:

-20°C to +50°C

Nominal Operating Temperature Range:

27°C ± 3°C


Charging Parameters

Standby Use (27°C):

Charging Voltage: 13.5 to 13.8V/battery

Charging Current: Max. 25% of rated capacity

Temperature Compensation: ±18mV/battery/°C

Cyclic Use (27°C):

Charging Voltage: 14.4 to 15.0V/battery

Charging Current: Max. 25% of rated capacity

Temperature Compensation: ±30mV/battery/°C

Self-Discharge:

<4% per month at 27°C


Constant Current Discharge Rating (Amperes) @ 27°C

ECV/Time 10 min 15 min 30 min 60 min 2 hrs 3 hrs 5 hrs 10 hrs 20 hrs
1.60 15.83 12.62 7.57 4.56 2.72 1.84 1.26 0.68 0.39
1.70 14.85 11.55 6.99 4.42 2.53 1.75 1.18 0.66 0.37
1.75 14.27 11.26 6.89 4.32 2.48 1.70 1.13 0.64 0.35
1.80 13.85 10.99 6.75 4.24 2.43 1.67 1.11 0.63 0.34

Constant Power Discharge Rating (Watts) @ 27°C

ECV/Time 10 min 15 min 30 min 60 min 2 hrs 3 hrs 5 hrs 10 hrs 20 hrs
1.60 193.7 152.2 90.0 56.3 34.7 22.7 15.5 8.3 4.4
1.70 190.1 141.9 86.0 54.3 31.7 21.5 14.6 8.2 4.3
1.75 180.3 136.8 84.2 53.3 30.4 21.0 14.2 8.1 4.2
1.80 170.5 131.7 82.4 52.2 29.0 20.6 13.8